Keywords: green storage, microgrid, capacity configuration, wind-solar-storage system, sparrow search algorithm. Citation: Zhu N, Ma X, Guo Z, Shen C and Liu J (2024) Research on the optimal capacity configuration of green storage microgrid based on the improved sparrow search algorithm. Front. Energy Res. 12:1383332. doi: …
To enhance the utilization of concentrated solar power (CSP), and reduce the wind abandonment rate of wind power (WP) and the carbon emissions from the traditional coal-fired unit (CFU), this study introduces oxygen-enriched combustion capture technology to retrofit the conventional CFU, and configures CSP with heat recovery unit …
First, according to the behavioral characteristics of wind, photovoltaics, and the energy storage, the hybrid energy storage capacity optimization allocation model is established, and its economy is nearly 17% and 4.7% better than that of single HES and single CAES, respectively.
Particle swarm optimization (PSO) algorithm is utilized to determine the optimum size and operational energy management within the system. The results show that after the regulation of the energy storage system, the power redundancy and shortage of the hybrid energy system are greatly reduced with the decreases by 85.08% and …
During the global energy crisis, a significant influx of renewable energy sources was connected to the power grid, resulting in adverse fluctuations. To address this challenge and simultaneously reduce environmental pollution, a hybrid energy storage system containing hydrogen energy storage (HES) and compressed air energy …
This work aims to optimize the capacity of two types of the off-grid hybrid wind-hydrogen energy system. We considered the maximum profit of the system and the minimum loss of power supply ...
In the configuration of energy storage, energy storage capacity should not be too large, too large capacity will lead to a significant increase in the investment cost. Small energy storage capacity is difficult to improve the operating efficiency of …
Because the new energy is intermittent and uncertain, it has an influence on the system''s output power stability. A hydrogen energy storage system is added to the system to create a wind, light, and hydrogen integrated energy system, which increases the utilization rate of renewable energy while encouraging the consumption of renewable …
To promote the development of green industries in the industrial park, a microgrid system consisting of wind power, photovoltaic, and hybrid energy storage (WT-PV-HES) was constructed. It effectively promotes the local consumption of wind and solar energy while reducing the burden on the grid infrastructure. In this study, the analytic …
(3) In order to improve the economic benefits of the wind-solar-hydrogen complementary multi-energy complementary system, the capacity configuration optimization model of the system is established. And the differential evolution algorithm is used to optimize the capacity configuration. The system investment construction cost …
For the individually configured energy storage systems, the total capacity is 698.25 + 1468.7613 + 2580.4475 = 4747.4588 kW h, while the optimal shared energy storage capacity configuration is 4258.5857 kW h, resulting in further reduction.
Capacity configuration optimization of a hybrid renewable energy system with hydrogen storage Int J Green Energy, 19 ( 14 ) ( 2022 ), pp. 1583 - 1599 CrossRef View in Scopus Google Scholar
For this purpose, the authors put forward a capacity optimization configuration for non-grid-connected wind-hydrogen hybrid energy storage system, in view of the features of hydrogen production ...
According to the principle of cost and value optimization, energy storage capacity is optimized according to Eq. (19).Assuming a price of $0.15/kWh, the stand-by and curtailment costs are 1.5 times the reasonable price of $0.225/kWh. It …
There are two ways to configure hydrogen energy storage for WPPs: Case 1 Individual HES. The WPP incorporates hydrogen energy storage, utilizing its …
Zhang et al. [20] used a multi-objective optimization model to determine the optimal sizing of a multi-energy system with hydrogen storage tanks, which was solved by an improved non-dominated ...
During the global energy crisis, a significant influx of renewable energy sources was connected to the power grid, resulting in adverse fluctuations. To address Xiu Li Wang, Ru Qing Xu, Jian Hong Zhang, Fu Shuan Wen, Chang Qing Liu; Optimal capacity allocation and economic evaluation of hybrid energy storage in a wind–photovoltaic …
Abstract: In order to improve the scheduling flexibility of grid connected wind power generation system, it is necessary to apply energy storage technology, and the main …
Compressed air energy storage (CAES) effectively reduces wind and solar power curtailment due to randomness. However, inaccurate daily data and improper storage Qihui Yu, Shengyu Gao, Guoxin Sun, Ripeng Qin; Optimization of wind and solar energy storage system capacity configuration based on the Parzen window …
The results showed that the cost of the system of hydrogen production by hybrid PV/wind energy with demand response was optimal, and the best system configuration was a grid-connected system containing a 548 kW PV, 1040 kW WT, 600 kW electrolyzer, and 600 kg hydrogen tanks.
In pursuit of widespread adoption of renewable energy and the realization of decarbonization objectives, this study investigates an innovative system known as a wind-solar-hydrogen multi-energy supply (WSH-MES) system. This system seamlessly integrates a wind farm, photovoltaic power station, solar thermal power station, and …
Recently, offshore wind farms (OWFs) are gaining more and more attention for its high efficiency and yearly energy production capacity. However, the power generated by OWFs has the drawbacks of intermittence and fluctuation, leading to the deterioration of electricity grid stability and wind curtailment. Energy storage is one of the most …
In order to improve the scheduling flexibility of grid connected wind power generation system, it is necessary to apply energy storage technology, and the main key technology of energy storage system is how to determine the capacity configuration of energy storage system. Using the individual advantages of superconducting magnetic energy storage …
An Optimization Capacity Design Method of Wind/Photovoltaic/Hydrogen Storage Power System Based on PSO-NSGA-II. Lei Xing 1, Yakui Liu 2,3,*. 1 Yinchuan University of Energy, Wangtaibao, Yinchuan, 750100, China 2 Qingdao University of Technology, Qingdao, 266520, China 3 State Key Laboratory of Electrical Insulation and Power …
A particle swarm optimization with dynamic adjustment of inertial weight (IDW-PSO) is proposed to solve the optimal allocation scheme of the model in order to …
DOI: 10.1016/j.ijhydene.2023.08.029 Corpus ID: 260996622 Capacity optimization of a wind-photovoltaic-electrolysis-battery (WPEB) hybrid energy system for power and hydrogen generation This study presents a data-driven …
An optimal capacity configuration model based on gravity energy storage is set up. • Efficiency and reliability indexes are set to evaluate the hybrid system performance. • Simulation proves GESS cost least comparing to BESS and CAES. • The GESS has a broad
An optimization program of a hybrid energy system model composed of the wind turbines (WT), photovoltaic panels (PV), reversible solid oxide cell (RSOC) …
DOI: 10.1016/j.est.2024.111107 Corpus ID: 268301551 Bi-level configuration and operation collaborative optimization of shared hydrogen energy storage system for a wind farm cluster Energy management of a virtual power plant (VPP) that consists of wind farm ...